ATTENTION: Fabricmate will be closed on Monday, September 7th, 2020 in observance of the Labor Day holiday. Any orders placed after Thursday, September 3rd will most likely be shipped on Tuesday, September 8th at the earliest. We apologize for any inconvenience this may cause. Fabricmate wishes you and your Family a happy and safe holiday.

An Updated Message to our Partners about Coronavirus (COVID-19).
Fabricmate hopes you and your family are staying safe and healthy during this time.
We are open and we are here for you! - read more...

  • The Ultimate Wall Finishing System
  • |
  • Buy Direct
  • |
  • Need assistance? Call us at 1-866-622-2996

Section 09 84 14 - 0.5 in. Tackable & Acoustical - Square Edge, Regular Density Core 9.4 pcf

170 views
0 Likes
0 0
CSI Spec for 1/2" Site-Fabricated Tackable & Acoustical Wall System with Square Edge profile and Regular Density (9.4 PCF) Core.

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select page to start with

6.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 6 OF 6  2. All certificates of warranty must  include the Manufacturer’s Pr oject Registration Number,  which must be obtained by insta ller prior to the date of instal lation. Project Registration  Numbers may not be obtained afte r the installati on has commence d.  3. Warranty Certificates without a M anufacturer’s Project Registra tion Number shall be  deemed as invalid and unenforceable.    3.05 SECURITY  A. Contractor shall meet all require ments, as described by Califor nia Education Code §45125.1.    END OF SECTION 09 84 14 

1.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 1 OF 6  SECTION 09 84 14  1/2” SITE FABRICATED TACKABLE/ACOUSTICAL WALL SYSTEM  Square Edge, Regular Density ReCore    PART 1 — GENERAL  1.01 SUMMARY  A. Provide Site Fabricated Tackable /Acoustical Wall Systems as sho wn on the drawings, as specified  herein and as needed for a complete and proper installation.  B. Contractor will provide Manufactu rer’s Standard Fabric Replacem ent Warranty.  C. Contractor will perform a “value engineering” review of provide d drawings, seeking product  manufacturers input as appropriat e, and make recommendations fo r the benefit of the project.    1.02 RELATED WORK  A. Documents affecting work of this  section include, but are not n ecessarily limited to, General  Conditions, Supplementary Conditions, and sections in Division  1 of these Specifications.    1.03  SUBMITTALS  A. General: Submit five (5) copies  of the following in accordance  with Conditions of Contract and  Division 1 Specification Sections.  B. Product Data: Submit manufacture r’s technical data, installatio n instructions, and maintenance and  cleaning instructions.  C. Certified Test Reports: Submit tes t data for the manufacturer’s  products from an independent  testing agency, accept able to authorities having jurisdiction,  evidencing the panel components  and/or assemblies comply with requirements indicated for Tackab le/Acoustical and fire  performance characteristics.  D. Provide a copy of the Manufacturer’s Standard Fabric Replacemen t Warranty and Manufacturer’s  Lifetime Warranty on Track, 10‐Ye ar Warranty on ReCore certific ates, available at manufacturer’s  website: www.fabricmate.com. All Warranty Certificates must inc lude the Project Registration  Number to ensure validity of Ma nufacturer’s Warranty. Warranty  certificates witho ut a registration  number are not valid.  E. Samples:  1. Fabric — Submit manufacturer’s st andard size swatches of Tackab le/Acoustical fabric.  2. Core Material — Submit 8 ½“X 11“  samples of each core material  used, showing full range of  materials, thicknesses, acoustics, and densities. 

5.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 5 OF 6  1. Follow contours of the wall and sc ribe to adjoining work accura tely at borders, penetrations,  and imperfections.  2. Track around all openings within a panel when needed as per man ufacturer’s instructions.  3. Allow adequate spacing for insertion of installation tool.  4. Wrap fabric around outside corner s in one piece without seams o r joints, creating one panel  on two different wall planes. Fabric shall float over the corne r matching the adjacent track’s  detail.  C. Core Material — Prep surfaces that receive treatment; remove wa ll plates and other obstacles.  Attach core to mounting surface  per manufacturer’s specificatio ns. Cut core material to accurately fit  inside tracked perimeter, mainta ining the same plane. Mechanica lly fasten core to prevent air gaps  between core and wall and to assure proper adhesion.  1. Assure that all fixtures have  the necessary backing to keep the m flush with the  Tackable/Acoustical panels.  D. Fabrics — Stretch fabric into th e track’s locking jaws using th e manufacturer’s recommended “rolling  tool”, keeping fabric weave plumb, level and true in proper rel ation to the building lines without  ripples, waviness, or “hourglass” effects.  1. Use of adhesives or mechanical fasteners is strictly prohibited .  2. The Fabricmate “floating‐fabric”  design shall not be compromise d. Fabric shall not be glued  or attached to the core  material in any way.  3. Fabric shall be stretched and tensioned sufficiently taut to av oid sagging under varying year‐ round temperature and humidity conditions.  4. Fabric shall maintain its shape after being touched or leaned a gainst without leaving any  indentations, sags, or blisters.  5. Ceiling applications shall not de viate more than 1” from true p lane of ceiling in 20’ span.    3.03 CLEANING AND PROTECTION  A. Clean exposed surfaces of Tackab le/Acoustical panels; comply wi th manufacturer’s instructions for  cleaning and repair of minor finish damage. Remove and replace  work that cannot be successfully  cleaned and repaired to permanen tly eliminate evidence of damag e.  B. The sub‐contractor shall advise the general contractor of the r equired protection for the Fabricmate  Systems panels, such as; temperature and humidity limitations a nd dust control, so that the finished  work will be without damage and de terioration at the time of ac ceptance by the Owner/District.    3.04 WARRANTY  A. All tackable and Tackable/Acous tical wall and ceiling panels sh all have a warranty against defects or  workmanship of not less than 5‐Years, commencing on the date of  substantial completion.  1. Contractor shall provide a Standa rd Fabric Replacement Warranty . 

4.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 4 OF 6  D. Tackable/Acoustical wall panels:  Fabricmate Systems Site‐fabric ated track system. No substitutions  accepted.  1. Track profile: Fabricmate Syste ms FS100, FS105 and FS110 for pe rimeter and FS100 for  intermediate joints as indicated on drawings.  2. ReCore polyester core material:  1/2” thick, 9.4 pcf white, cer tified tackable, ASTM E84 rated  insulation board to fit within t rack’s perimeter.  Said board t o have a minimum 50% post‐ consumer content.  Material dens ity to be consistent throughout  the material.  3. Fabrics:  Suitable for the particular appl ication, as selected by the Arc hitect/Designer from  the Manufacturer’s Standard Fabric offering. Information regard ing Fabric Application,  Performance and Pricing Group is  available at the manufacturer’ s website:  www.fabricmate.com.  i. Fabric Manufacturer: ________________________________________  ii. Fabric Pattern: ______________________________________________  iii. Fabric Width: _______________________________________________  iv. Fabric Color: ________________________________________________  v. Fabric Pricing Group: ______  4. Accessory Package: Supply one Fabricmate FS670 Accessory Packag e for each room with  Tackable/Acoustic panels.    PART 3 — EXECUTION  3.01 INSPECTION    A. Contractor must examine substrat es and conditions under which t he Tackable/Acoustical system is  to be applied and notify the Arc hitect in writing of conditions  detrimental to proper and timely  completion. Do not proceed with  work until unsatisfactory condi tions have been deemed corrected  and acceptable to contractor.  B. Verify all stationary objects abutting Tackable/Acoustical pane ls are installed (i.e. casework, marker  boards, door and window jams, c eiling) prior to installation.    3.02 INSTALLATION    A. Install Tackable/Acoustical wall  panels in locations indicated  on plans. Comply with manufacturer’s  printed instructions for installi ng site‐fabricated track syste ms.  B. Track: Install perimeter and inte rmediate track using screws, a nchors and staples as project  conditions warrant. Secure track b ase to wall (or ceiling) to p revent track framewo rk from separating  away from the wall. For masonry s urfaces use a continuous bead  of PL200 or equal with conical  anchor and pin/nail/rivets every 6‐8 inches per manufacturer’s  recommendation. 

2.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 2 OF 6  3. Track — Submit samples of manufac turer’s “Track” or “Frame” sho wing full range of edge  profiles, thicknesses, and details for each type of Tackable/Ac oustical panel. Where more  than one edge profile is used on  a panel, clearly show how each  edge profile transitions into  a different edge profile.  4. Samples — Provide 8 ½“X 11“sample s of each type of panel used,  including representative  samples of each thickness and pa nel type. Install samples on a  substrate of sufficient  firmness to allow the samples to be handled without damage.  5. Accessory Package: Submit one F abricmate FS670 Accessory Packag e.    1.04  QUALITY ASSURANCE  A. Contractor: Provide verifiably genuine products for each type o f wall panel as produced by the  manufacturer(s), including recommended primers, adhesives, and  sealants. The manufacturer’s  published product literature shall clearly indicate compliance  of wall panels with requirements  indicated.  B. Both individual components and finished assemblies shall meet t he following as appropriate:  1. Thickness: 1/2", Density: 9.4 pcf.  2. Fire Performance Characteristics : Provide Tackable/Acoustical w all panels with surface‐ burning characteristics as indica ted below, as determined by te sting assembled materials  and construction according to AS TM E‐84 Class A,  by a testing o rganization acceptable to  authorize having jurisdiction.  i. Flame Spread: 25 or less  ii. Smoke Developed: 450 or less  3. Sound Absorption Characteristics:  Provide Tackable/Acoustical w all panels with a noise  reduction coefficient (NRC) of 0.5 or better.  4. Be free of volatile organic compounds (VOCs).  5. Fungi Resistance Certification of core material in accordance w ith ASTM C 1338.    1.05  DELIVERIES, STORAGE, AND HANDLING  A. Protect the Fabric, core materia l, and track from excessive moi sture in shipment, storage, and  handling. Deliver in unopened bun dles and store in a dry place  with adequate air circulation. Do not  deliver material until wet work s uch as concrete and plaster ha s been completed.    1.06  PROJECT CONDITIONS  A. Do not begin installation until sp aces to receive Tackable/Acou stical panels have  been enclosed and  maintained at approximately the  same humidity and temperature c onditions as planned for  occupancy. Maintain temperature conditions as recommended by pa nel manufacturer.    1.07  EXTRA MATERIALS   A. The following extra materials are to be provided: 

3.      PROJECT NAME    DATE      PROJECT OWNER                  BID NO. ______  SITE FABRICATED  TACKABLE/ACOUSTICAL WALL SYSTEM  09 84 14 — 3 OF 6  1. Accessory Package: Installer sha ll provide extra 10 Percent of  the FS670 Accessory Packages  issued, but no less than 1 extra unit.  2. Contractor to provide Owner/Dist rict additional system material s at manufacturer’s current  retail price.  3. No free fabric to be provided, e xcept as provided by the Manufa cturer’s Standard Fabric  Replacement Warranty.    PART 2 — PRODUCTS  2.01   TACKABLE/ACOUSTICAL  WALL PANEL MATERIALS  A. Available Manufacturers: Subject  to compliance with requirement s, the product used as basis‐of‐ design is provided by the manufacturer listed below:    B. Tackable/Acoustical Site‐fabricated Track System, as distribute d by Fabricmate Systems, Inc.,  P:(805)642‐7470, F:(805)642‐3154, Toll Free:(866)622‐2996, www. fabricmate.com. No substitutions  accepted.  1. Contractor shall provide a Standa rd Fabric Replacement Warranty .  C. Design Requirements:  1. Stretched fabric panel system sh all consist of continuous perim eter and intermediate  mounting extrusions that are site  fabricated, and applied direc tly to the wall surface.   2. Fabric face shall be s tretched over core mat erials and tucked i nto the track’s locking jaws,  leaving fabric floating above core surface. Installation of fab ric facing shall not utilize any  adhesives, nails, tacks, screws,  sewn seams, thermally bonded s eams, or tape.  3. Systems shall allow for removal a nd replacement of fabric from  individual panels. Removal of  fabric shall provide access to sur face behind fabric. Fabric sh all be removable and  replaceable without dismantling, removal, damaging, or replacem ent of the track extrusions  or core material.  4. All fabrics shall be evaluated  by the contractor for suitabilit y with its system, the intended  application, and for warranty pur poses.  When uncertain, the co ntractor should consult with  the system manufacturer.  5. Framework: One‐piece extruded polymer track system with jaws of  sufficient strength to  securely hold fabric in place after repeated applications. Mini mum track wall thickness  specification shall be .065”.  T rack style and color (standard  colors or specified PMS color) to  be selected by architect.  6. Edge detail: Square.  7. Intermediate detail: Square.  8. Outside Corner Detail: Fabric sh all wrap around MDF backed corn ers in one piece without  seams or joints unless otherw ise indicated or necessary.  9. Prefabricated panels “fabric or vinyl wrapped” do not satisfy t he intent of this specification  and will not be accepted.  10. Hinged, self‐locking (snap‐lock) type mounting extrusions do no t satisfy the intent of this  specification and will not be accepted.  11. Fire resistance: Complete panel  assembly shall have an ASTM E‐8 4 Class A. 

Views

  • 170 Total Views
  • 68 Website Views
  • 102 Embedded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+

Embeds 6

  • 112 www.fabricmate.com
  • 550 www.google.com
  • 41
  • 1 some-inexistent-website.acu
  • 3 testasp.vulnweb.com
  • 1 hitceL9JThg3D.bxss.me