ATTENTION: Fabricmate will be closed on Monday, September 7th, 2020 in observance of the Labor Day holiday. Any orders placed after Thursday, September 3rd will most likely be shipped on Tuesday, September 8th at the earliest. We apologize for any inconvenience this may cause. Fabricmate wishes you and your Family a happy and safe holiday.

An Updated Message to our Partners about Coronavirus (COVID-19).
Fabricmate hopes you and your family are staying safe and healthy during this time.
We are open and we are here for you! - read more...

  • The Ultimate Wall Finishing System
  • |
  • Buy Direct
  • |
  • Need assistance? Call us at 1-866-622-2996

Section 09 84 14 - 1 in. Acoustical & Graphic - Square Edge, Regular Density Core 9.4 pcf

CSI Specifications / Full-Line® 1 inch

150 views
0 Likes
0 0
CSI Spec for 1" Site-Fabricated Acoustical Graphic Print Wall System with Square Edge profile and Regular Density (6.0 PCF) Core.

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select page to start with

6. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 6 OF 6 A. Con tractor shall meet all requirements, as described by California Education Code §45125.1. END OF SECTION 09 84 14

1. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 1 OF 6 SECTION 09 84 14 1 ” SITE FABRICATED ACOUSTICAL GR A PHIC PRINT WALL SYSTEM Square Edge, Regular Density ReCore PART 1 — GENERAL 1.01 SUMMARY A. Provide Site Fabricated Acoustical Graphic P rint Wall Systems as shown on the drawings, as specified herein and as needed for a complete and proper installation. B. Contractor will perform a “value engineering” review of provided drawings, seeking product manufacturers input as appropriate, and make recommendations for the benefit of the project. 1.02 RELATED WORK A. Documents affec ting work of this section include, but are not necessarily limited to, General Conditions, Supplementary Conditions, and sections in Division 1 of these Specifications. 1.03 SUBMITTALS A. General: Submit five (5) copies of the following in accordance with Conditions of Contract and Division 1 Specification Sections. B. Product Data: Submit manufacturer’s technical data, installation instructions, and maintenance and cleaning instructions. C. Certified Test Repor ts: Submit test data for the manufacturer’s products from an independent testing agency, acceptable to authorities having jurisdiction, evidencing the panel components and/or assemblies comply with requirements indicated for acoustical and fire performance characteristics. D. Provide a copy of the Manufacturer’s Lifetime Warranty on Track, 10 - Year Warranty on ReC ore certificates. All Warranty Certificates must include the Project Registration Number to ensure validity of Manufacturer’s Warranty. Warranty certi ficates without a registration number are not valid. E. Samples: 1. Fabric — Submit manufacturer’s standard size swatches of printed fabric to demonstrate ability to render fine detail and smooth gradients on acoustic fabric . 2. Core Material — Submit 8 ½ “ X 11 “ samples of each core material used, showing full range of materials, thicknesses, acoustics, and densit ies .

5. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 5 OF 6 C. Core Material — Prep surfaces that receive treatment; remove wall pl ates and other obstacles. Attach core to mounting surface per manufacturer’s specifications . Cut core material to accurately fit inside tracked perimeter, maintaining the same plane. Mechanically fasten core to prevent air gaps be tween core and wall and to assure proper adhesion. 1. Assure that all fixture s have the necessary backing to keep them flush with the acoustical graphic print panels. D. Fabrics — S tretch fabric into the track’s locking jaws using the manufacturer’s recommended “rolling tool”, keeping fabric weave plumb, level and true in proper relation to the building lines without ripples, waviness, or “hourglass” effects. 1. Use of adhesives or mechanical fasteners is strictly prohibited. 2. The Fabricmate “floating - fabric” design shall not be compromised. Fabric shall not be glued or attached to the core material in any way. 3. Fabric shall be stretched and tensioned sufficiently taut to avoid sagging under varying year - round temperature and humidity conditions. 4. Fabric shall maintain its shape after being touched or leaned against without leaving any indentations, sags, or blisters. 5. Ceiling applications shall not deviate more than 1” from true plane of ceiling in 20’ span. 3.03 CLEANING AND PROTECTION A. Clean exposed surfaces of acoustical graphic print panels; comply with manufacturer’s instructions for cleaning and repair of minor finish damage. Remove and replace work that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage. B. The sub - contractor shall advise the general contractor of the required protec tion for the Fabricmate Systems panels, such as; temperature and humidity limitations and dust control, so that the finished work will be without damage and deterioration at the time of acceptance by the Owner/District. 3.04 WARRANTY A. All tackable and acoustical wall and ceiling panels shall have a warranty against defects or workmanship of not less than 5 - Years, commencing on the date of substantial completion. 1. All certificates of warranty must include the Manufacturer’s Project Registration Number, which must be obtained by installer pri or to the date of installation. Project Registration Numbers may not be obtained after the installation has commenced. 2. Warranty Certificates without a Manufacturer’s Project Registration Number shall be deemed as invalid and unenforceable. 3.05 SECURITY

2. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 2 OF 6 3. Track — Submit samples of manufacturer’s “Track” or “Frame” showing full range of edge profiles, thicknesses, and details for e ach type of acoustica l graphic print panel. Where more than one edge profile is used on a panel, clearly show how each edge profile transitions into a different edge profile. 4. Samples — Provide 8 ½ “X 11 “samples of each type of panel used, including representative samples of eac h thickness and panel type. Install samples on a substrate of sufficient firmness to allow the samples to be handled without damage. 1.04 QUALITY ASSURANCE A. Contractor: Provide verifiably genuine products for each type of wal l panel as produced by the manufacturer (s) , including recommended primers, adhesives, and sealants. The manufacturer’s published product literature shall clearly indicate compliance of wall panels with requirements indicated. B. Both individual components and fin ished assemblies shall meet the following as appropriate: 1. Thickness: 1", Density: 6 pcf. 2. Fire Performance Characteristics: Provide acoustical graphic print wall panels with surface - burning characteristics as indicated below, as determined by testing as sembled materials and construction according to ASTM E - 84 Class A , by a testing organization acceptable to authorize having jurisdiction. i. Flame Spread: 25 or less ii. Smoke Developed: 4 5 0 or less 3. Sound Absorption Characteristics: Provide acoustical graphic print wall panels with a noise reduction coefficient (NRC ) of 0. 7 or better. 4. Be free of volatile organic compounds (VOCs). 5. Fungi Resistance Certification of core material in accordance with ASTM C 1338. 1.05 DELIVERIES, STORAGE, AND HANDLING A. Protect the Fabric, core material, and track from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver materia l until wet work such as concrete and plaster has been completed. 1.06 PROJECT CONDITIONS A. Do not begin installation until spaces to receive acoustical graphic print panels have been enclosed and maintained at approximately the same humidity and temperature c onditions as planned for occupancy. Maintain temperature conditions as recommended by panel manufacturer. 1.07 EXTRA MATERIALS A. No extra free materials are to be provided . 1. No additional printed fabric to be provided.

3. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 3 OF 6 2. Contractor to provide Owner/District additional system materials at manufacturer’s current retail price . PART 2 — PRODUCTS 2.01 ACOUSTICAL GRAPHIC PRINT WALL PANEL MATERIALS A. Available Manufacturers: Subject to compliance with requirements, the product used as basi s - of - design is provided by the manufacturer listed below: B. Acoustical Site - fabricated Track System, as distributed by Fabricmate Systems, Inc., P:(805)642 - 7470, F:(805)642 - 3154, Toll Free:(866)622 - 2996, www.fabricm ate.com . No substitutions accepted. 1. Contractor shall provide a Standard Fabric Replacement Warranty. C. Design Requirements: 1. Stretched fabric panel system shall consist of continuous perimeter and intermediate mounting extrusions that are site fabricated, and applied directly to the wall surface. 2. Fabric face shall be stretched over core materials and tucked into the track’s loc king jaws, leaving fabric floating above core surface. Installation of fabric facing shall not utilize any adhesives, nails, tacks, screws, sewn seams, thermal ly bonded seams, or tape. 3. Systems shall allow for removal and replacement of fabric from individu al panels. Removal of fabric shall provide access to surface behind fabric. Fabric shall be removable and replaceable without dismantling, removal, damaging, or replacement of the track extrusions or core material. 4. All fabrics shall be evaluated by the contractor for su itability with it s system, the intended application, and for warranty purposes . When uncertain, the contractor should consult with the system manufacturer. 5. Framework: One - piece extruded polymer track system with jaws of sufficient strengt h to securely hold fabric in place after repe ated applications. Minimum t rack wall thick ness specification shall be .065 ”. Track style and color (standard colors or specified PMS color) to be selected by architect. 6. Edge detail: Square . 7. Intermediate detail : Square. 8. Outside Corner Detail: Fabric shall wrap around MDF backed corners in one piece without seams or joints unless otherwise indicated or necessary . 9. Prefabricated panels “fabric or vinyl wrapped” do not satisfy the intent of this specification and wi ll not be accepted. 10. Hinged, self - locking (snap - lock) type mounting extrusions do not satisfy the intent of this specification and will not be accepted. 11. Fire resistance: C omplete panel assembly shall have an ASTM E - 84 Class A.

4. PROJECT NAME DATE PROJECT OWNER BID NO. ______ SITE FABRICATED ACOUSTICAL GRAPHIC PRINT WALL SYSTEM 09 84 14 — 4 OF 6 D. Acoustical graphic print wall panels: Fabricmate Systems Site - fabricated track system. No substitutions accepted. 1. Tr ack profile: Fabricmate Systems FS 1 5 0 , FS15 5 and FS 16 0 for perimeter and FS1 5 0 for intermediate joints as indicated on drawings. 2. ReC ore® polyester core material: 1 ” thick , 6 pcf white, certified tackable, ASTM E84 rated insulation board to fit within track’s perimeter. Said board to have a minimum 50% post - consumer content. Material density to be consistent throughout the material. 3. Fabrics: Manuf acturer’s Standard F abric for Digital Graphic Printed: Image must be selected and approved b y architect, upon consultation with the manufacturer’s graphic specialist with regards to image file suitability . PART 3 — EXECUTION 3.01 INSPECTION A. Contractor must examine substrates and conditions under which the acoustical graphic system is to be applied and notify the Arch itect in writing of conditions detrimental to proper and timely completion. Do not proceed with work until unsatisfactory conditions have been deemed corrected and acceptable to contractor . B. Verify all stationary objects abutting acoustical graphic print panels are installed ( i.e. casework, marker boards, doo r and window jams, ceiling ) prior to installation. 3.02 INSTALLATION A. Install acoustical graphic print wall panels in locations indicated on plans. Comply with manufacturer’s printed i nstructions for installing site - fabricated track systems. B. Track: Install perimeter and intermediate track using screws, anchors and staples as project conditions warrant. Secure track base to wall (or ceiling) to prevent track framework from separating away from the wall. For masonry surfaces use a continuous bead of PL200 or equal with conical anchor and pin /nail/rivets every 6 - 8 inches p er manufacturer’s recomme ndation. 1. Follow contours of the wall and scribe to adjoining work accurately at borders, penetrations, and imperfections. 2. Track around all openings within a panel when needed as per manufacturer’s instructions. 3. Allow adequate spacing for insertion of installation tool. 4. Wrap fabric around outside corners in one piece without seams or joints, creating one panel on two different wall planes. Fabric shall float over the corner matching the adjace nt track’s detail.

Views

  • 150 Total Views
  • 48 Website Views
  • 102 Embedded Views

Actions

  • 0 Social Shares
  • 0 Likes
  • 0 Dislikes
  • 0 Comments

Share count

  • 0 Facebook
  • 0 Twitter
  • 0 LinkedIn
  • 0 Google+

Embeds 6

  • 114 www.fabricmate.com
  • 540 www.google.com
  • 41
  • 1 some-inexistent-website.acu
  • 3 testasp.vulnweb.com
  • 1 hit5UWHHb7Jzm.bxss.me